JT-800KW Perkins Generator

  • 12-Month Warranty
  • Factory Direct Price
  • Fast Global Shipping
  • 24/7 WhatsApp Support

PRP: 800 kW / 1000 kVA

Standby: 880 kW / 1100 kVA

Engine: 4008TAG2A

Free consultation:
Product Overview

JT‑800KW Perkins Generator | 1000kVA Prime Power

800 kW Prime / 880 kW Standby | Perkins 4008TAG2A | 400/230V 50Hz

Overview ▾

The JT‑800KW runs the Perkins 4008TAG2A — an 8‑cylinder 30.56L inline turbocharged diesel engine rated at 800kW prime power with 880kW standby capacity. It targets regional hospital backup systems, telecom tower clusters, smaller data center installations, and mid‑tier mining operations across Europe, Africa and Southeast Asia. At 10.5t and 6,000mm length, it is the lightest and most compact generator in JUTOP's 800kW+ range — fitting standard flat‑rack ocean freight containers without width or height overhang charges that apply to wider V‑configuration units.

Applications

JT‑800KW 1000kVA Perkins generator with CE SONCAP PVoC certification for industrial mining telecom data center critical power

· Large‑Scale Industrial Facility Continuous Power

· Mining Site Off‑Grid Supply

· Regional Data Center Standby Power

· Commercial Mega‑Complex Backup Power

· Telecom Core Infrastructure Power

· Remote Heavy‑Industry Site Supply

· Healthcare Campus Emergency Power

Specifications

ModelJT‑800KW
Prime Power800 kW / 1000 kVA
Standby Power880 kW / 1100 kVA
Voltage / Frequency400/230V · 50Hz
Rated Current1440 A
Engine ModelPerkins 4008TAG2A, 8‑Cyl In‑Line Turbocharged
Displacement30.56 L
Bore × Stroke160 × 190 mm
Compression Ratio13.6:1
Cycle Type4‑Cycle Diesel
Engine Rated Speed1500 RPM
Peak Torque @ 1500RPM4,200 N·m
Cooling SystemWater‑Cooled
Engine Oil Capacity72 L
Start Motor Voltage24V DC
Alternator TypeBrushless, Self‑exciting, H‑Class Insulation, 3‑Phase
Phase & Connection3‑Phase 4‑Wire
Power Factor0.8 lagging
Insulation ClassClass H
Protection GradeIP21
Total Harmonic Distortion (THD)<5%
Fuel @ 50% Load186‑194 g/kW·h (Perkins 4008TAG2A datasheet)
Fuel @ 75% Load202‑210 g/kW·h (Perkins 4008TAG2A datasheet)
Fuel @ 100% Load218‑226 g/kW·h (Perkins 4008TAG2A datasheet)
Fuel Tank Capacity1,600 L (≈7 Hours @ 75% Load)
Scheduled Maintenance Interval500 Working Hours
Noise Level78‑80 dB(A) @ 1 Meter
Max Operating Altitude≤1,000 m (no derate)
Max Parallel UnitsUp to 8 Units (IEC 8528‑5)
ATS CompatibilityYes
Transport Dimensions6,000 × 2,200 × 2,600 mm
Overall Weight10.5 t
CertificationsISO9001 · CE · SONCAP · PVoC · NRCS · SIRIM · SNI · TISI
Production Lead Time40‑45 Working Days
Shipping Lead Time40‑50 Days Ocean Freight
Payment Term30% Advance, 70% Before Shipment

Why Choose the JT‑800KW

1. 800kW Prime — Single‑Unit Alternative to Dual‑400kW Parallel Systems ▾

The Perkins 4008TAG2A delivers continuous 800kW prime power per Perkins 4008TAG2A power curve data, with 880kW standby available for 1 hour per Perkins standard operating cycle. For projects with a known 700‑800kW load profile, the choice is typically between two 400kW sets in parallel or a single 800kW unit. Two 400kW sets add synchronization equipment, dual fuel filters, dual control panels and two load‑sharing failure points. One JT‑800KW eliminates that complexity and costs less per kilowatt than the combined price of two 400kW units.

2. Inline‑8 Layout — Most Cost‑Effective Shipping Configuration for Global Projects ▾

The 4008TAG2A is an 8‑cylinder inline engine rather than a V‑configuration. At 10.5t and 6,000mm length with a 2,200mm width, it fits standard ISO flat‑rack containers without width overhang. V‑configuration units at 1,000‑1,500kW often exceed 2,400mm width and require specialized breakbulk shipping — adding $3,000‑8,000 in freight cost per unit. For operators ordering 2‑5 units, the inline‑8's transport dimensions mean standard ocean freight and simpler port handling without heavy‑lift equipment surcharges.

3. 4,200 N·m Optimized Torque — Reliable Motor Startup at Economical Partial Loads ▾

The 4008TAG2A produces 4,200 N·m peak torque at 1500RPM versus the older 4008TAG1A at 3,850 N·m — a 9.1% improvement per Perkins 4000 series datasheet. The practical benefit: this torque handles the locked‑rotor current of standard industrial motors (pumps, compressors, fans) without stalling. The 4008TAG2A reaches peak torque output at lower RPM than its predecessor, meaning it recovers faster from load steps at the engine speed most generators run at during continuous operation. At 75% load — the typical operating point for backup and prime power sets — the engine runs in its most efficient fuel band rather than being pushed toward full‑load enrichment.

4. Ultra‑Low 78‑80 dB(A) — Enables Semi‑Enclosed & Rooftop Installations ▾

The 800kW unit runs at 78‑80 dB(A) at 1 meter — 2‑4 dB lower than most 1,000kW+ units. This does not make it a quiet generator, but it does shift the noise problem from "requires custom acoustic enclosure" to "standard industrial treatment sufficient." For telecom rooftop sites, enclosed industrial building basements and hospital plant rooms, 78‑80 dB(A) at source means a standard 15‑20 dB acoustic enclosure brings boundary noise to acceptable commercial zone levels without the engineering cost of a custom high‑specification canopy.

5. Industrial‑Grade DTC Diagnostics — Cut Repeat Site Visits for Remote Multi‑Unit Fleets ▾

The JT‑800KW includes an industrial‑grade LCD panel with Diagnostic Trouble Code (DTC) capability. For telecom and hospital operators with multi‑unit fleets across dispersed sites, remote DTC readout means the first technician dispatched carries the correct replacement part from the first visit — not after a second trip to diagnose what failed. At $200‑500 per site visit in remote regions, cutting one repeat visit per unit per year pays for the diagnostic panel upgrade within the first service cycle.

6. 500‑Hour Maintenance + Global Perkins Parts Network — Simplified Long‑Term Fleet Management ▾

Perkins specifies 500 working hours between scheduled services for the 4008TAG2A. For telecom tower operators running 24/7 base station backup, this interval means approximately one service event every 3‑4 weeks per unit. The Perkins distributor network covers over 90 countries — meaning common wear parts (air filters, oil filters, fuel filters, injector seals) are procurable from local Perkins dealers rather than requiring shipment from China. For operators managing 20+ units across a region, local parts access changes maintenance from a logistical operation to a routine scheduling exercise.

Get a Custom Quote

· Factory‑direct pricing — no intermediaries. Full technical datasheets and configuration tailored to your site conditions.

· Delivery: 30–35 business days · Payment: 30% advance, 70% on completion

· Certifications: ISO 9001 · CE · NOM · RETIE · INMETRO · ANCAP
· Technical inquiry response: within 1–2 business days. Volume pricing available.

Company Profile

Shandong Jutop Heavy Industry Technology Co., Ltd. is a national high-tech heavy machinery manufacturer founded in 2013. Equipped with a 50,000㎡ workshop and over 300 professionals, we specialize in R&D and export of construction machinery, drilling rigs and generators. Boasting 200+ patents and global certifications, our products are exported to over 120 countries, dedicated to supplying reliable cost-effective equipment for worldwide clients.

Certificate

Request a Quote
Submit your questions via the form below for a response within 1 business day.
Recommended Products

Contact Us

Submit your questions via the form below for a response within 1 business day.